Validação da metodologia de ensaio imunoenzimático comercial para diagnóstico de rotavírus visando estudos clínicos no Brasil

xmlui.dri2xhtml.METS-1.0.item-date
2015xmlui.dri2xhtml.METS-1.0.item-files-viewOpen
xmlui.mirage2.itemSummaryView.MetaData
xmlui.ArtifactBrowser.ItemViewer.show_fullxmlui.dri2xhtml.METS-1.0.item-uri
http://patua.iec.gov.br//handle/iec/2994xmlui.dri2xhtml.METS-1.0.item-author
Gonçalves, Maryelle dos Santos
Pereira, Adriana Gisele Cruz
Prazeres, Raimunda Alberta Castro dos
Mascarenhas, Joana D'Arc Pereira
Justino, Maria Cleonice Aguiar
Souza, Lorena Lopes de
Linhares, Alexandre da Costa
Muller, Elza Caroline Alves
xmlui.dri2xhtml.METS-1.0.item-abstract
Os rotavírus do grupo A (RV-A) causam doenças diarreicas que acometem principalmente crianças menores de 5 anos
de idade. Estima-se que, anualmente, haja 130 milhões de casos de diarreia por RV-A, com 453.000 mortes e 2 milhões
de hospitalizações. O ensaio imunoenzimático apresenta elevada sensibilidade e praticidade e, por isso, vem sendo
amplamente empregado na rotina laboratorial para detecção de RV-A. Este trabalho objetivou avaliar o desempenho
do teste imunoenzimático RIDASCREEN® Rotavirus, frente ao ensaio de referência Premier™ Rotaclone® Rotavirus,
analisando-se especificidade, sensibilidade, precisão, interferência, reprodutibilidade e estabilidade do ensaio. Foram
utilizadas 40 amostras fecais, coletadas no período de maio de 2008 a maio de 2009, provenientes de unidades de
saúde pediátricas em Belém, Estado do Pará, Brasil, com testes realizados na Seção de Virologia do Instituto Evandro
Chagas. O resultado apontou 90% (36/40) de concordância entre as duas metodologias, com sensibilidade de 90%
(27/30) e especificidade de 100% (10/10). Não houve variação em relação à precisão, interferência, reprodutibilidade
e estabilidade do teste de RIDASCREEN® frente ao Rotaclone®. Os resultados obtidos neste estudo indicam que o teste
de RIDASCREEN® possui desempenho semelhante ao do "padrão-ouro", podendo ser adotado na rotina laboratorial. Group A rotaviruses (RV-A) cause diarrheic disease that occur especially in children under 5 years old. Annually,
130 million diarrhea cases by RV-A are estimated, with 453,000 deaths and 2 million cases of hospitalizations. The
immunoenzymatic assay presents a high sensibility and convenience, and it has been widely used in lab routine work in
the RV-A detection. This study aimed to evaluate the development of RIDASCREEN® Rotavirus in relation to the Premier™
Rotaclone® Rotavirus reference test, analyzing specificity, sensitivity, accuracy, interference, reproducibility and stability
of that assay. Forty fecal samples were used, collected from May 2008 to May 2009 of the children's health centers
in Belém, Pará State, Brazil with tests that were conducted at the Virology Section of the Instituto Evandro Chagas.
The results showed 90% (36/40) of matching between those two methodologies, with sensibility of 90% (27/30) and
specificity of 100% (10/10). There was no change on accuracy, interference, reproducibility and stability of RIDASCREEN®
test in relation to Rotaclone®. The results obtained by this study indicated that RIDASCREEN® has similar development comparing to the gold standard test, so it can be used in the lab routine work.
xmlui.dri2xhtml.METS-1.0.item-citation
GONÇALVES, Maryelle dos Santos et al. Validação da metodologia de ensaio imunoenzimático comercial para diagnóstico de rotavírus visando estudos clínicos no Brasil. Revista Pan-Amazônica de Saúde, v. 6, n. 3, p. 13-19, set. 2015. Disponível em: <http://scielo.iec.pa.gov.br/scielo.php?script=sci_arttext&pid=S2176-62232015000300002&lng=pt&nrm=iso&tlng=pt >. Acesso em: 22 fev. 2018.xmlui.dri2xhtml.METS-1.0.item-decsPrimary
Infecções por Rotavirus / diagnósticoRotavírus
Gastroenterite
Diarreia Infantil
Ensaio de Imunoadsorção Enzimática / métodos